Advertisement
Original article| Volume 94, ISSUE 3, P444-450, March 2013

Download started.

Ok

Applicability and Test-Retest Reliability of Isokinetic Shoulder Abduction and Adduction in Women Fibromyalgia Patients

Published:August 20, 2012DOI:https://doi.org/10.1016/j.apmr.2012.08.198

      Abstract

      Objective

      To investigate the applicability and reliability of isokinetic strength measurements during concentric and eccentric actions of the shoulder muscles in fibromyalgia (FM) patients.

      Design

      Test-retest reliability study.

      Setting

      University laboratory.

      Participants

      Women with FM (N=25) aged 37 to 69.

      Interventions

      Not applicable.

      Main Outcome Measures

      Two isokinetic tests of the shoulder were repeated after an interval of 7 days. Each test involved 3 repetitions of abduction and adduction performed at a rate of 60°/s. The first test involved 2 concentric muscle actions (concentric/concentric test). The second test involved concentric abduction followed by eccentric adduction (concentric/eccentric test). Unilateral peak torque (Nm) and average work (J) were measured. Applicability was calculated as the proportion of participants who were able to complete every test. Reliability was analyzed by intraclass coefficient (ICC), standard error of measurement, and smallest real difference (SRD).

      Results

      Applicability was 84% for the concentric/concentric test and 52% for the concentric/eccentric test. The main factor influencing applicability was age. In the concentric/eccentric test, measurement of peak torque showed high reliability for the abduction (ICC=.88; standard error of measurement=1.82; SRD=5.05) and adduction (ICC=.89; standard error of measurement=3.83; SRD=10.62) phases. In the concentric/concentric test, measurement of peak torque showed low reliability in the abduction phase (ICC=.29; standard error of measurement=6.45; SRD=17.87) and excellent reliability in the adduction phase (ICC=.92; standard error of measurement=5.95; SRD=16.50).

      Conclusions

      The applicability of shoulder isokinetic tests in FM patients who are women may be affected by age. In comparison, the concentric/concentric test was more applicable and less reliable than the concentric/eccentric test during abduction and adduction. These findings will facilitate the clinical interpretation of changes in isometric and isokinetic shoulder adduction and abduction tests in women with FM.

      Keywords

      List of abbreviations:

      FM (fibromyalgia), FIQ (Fibromyalgia Impact Questionnaire), ICC (intraclass correlation coefficient), ROM (range of motion), SRD (smallest real difference)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Archives of Physical Medicine and Rehabilitation
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Maquet D.
        • Croisier J.L.
        • Renard C.
        • Crielaard J.M.
        Muscle performance in patients with fibromyalgia.
        Joint Bone Spine. 2002; 69: 293-299
        • Meyer B.B.
        • Lemley K.J.
        Utilizing exercise to affect the symptomology of fibromyalgia: a pilot study.
        Med Sci Sports Exerc. 2000; 32: 1691-1697
        • Nordenskiold U.M.
        • Grimby G.
        Grip force in patients with rheumatoid arthritis and fibromyalgia and in healthy subjects. A study with the Grippit instrument.
        Scand J Rheumatol. 1993; 22: 14-19
        • Redondo J.R.
        • Justo C.M.
        • Moraleda F.V.
        • et al.
        Long-term efficacy of therapy in patients with fibromyalgia: a physical exercise-based program and a cognitive-behavioral approach.
        Arthritis Rheum. 2004; 51: 184-192
        • Thomas A.W.
        • White K.P.
        • Drost D.J.
        • Cook C.M.
        • Prato F.S.
        A comparison of rheumatoid arthritis and fibromyalgia patients and healthy controls exposed to a pulsed (200 microT) magnetic field: effects on normal standing balance.
        Neurosci Lett. 2001; 309: 17-20
        • Valkeinen H.
        • Alen M.
        • Hannonen P.
        • Hakkinen A.
        • Airaksinen O.
        • Hakkinen K.
        Changes in knee extension and flexion force, EMG and functional capacity during strength training in older females with fibromyalgia and healthy controls.
        Rheumatology (Oxford). 2004; 43: 225-228
        • Henriksson K.G.
        • Backman E.
        • Henriksson C.
        • de Laval J.H.
        Chronic regional muscular pain in women with precise manipulation work. A study of pain characteristics, muscle function, and impact on daily activities.
        Scand J Rheumatol. 1996; 25: 213-223
        • Henriksson C.
        • Gundmark I.
        • Bengtsson A.
        • Ek A.C.
        Living with fibromyalgia. Consequences for everyday life.
        Clin J Pain. 1992; 8: 138-144
        • Lindh M.H.
        • Johansson L.G.
        • Hedberg M.
        • Grimby G.L.
        Studies on maximal voluntary muscle contraction in patients with fibromyalgia.
        Arch Phys Med Rehabil. 1994; 75: 1217-1222
        • Norregaard J.
        • Bulow P.M.
        • Lykkegaard J.J.
        • Mehlsen J.
        • Danneskiold-Samsooe B.
        Muscle strength, working capacity and effort in patients with fibromyalgia.
        Scand J Rehabil Med. 1997; 29: 97-102
        • Gusi N.
        • Tomas-Carus P.
        • Hakkinen A.
        • Hakkinen K.
        • Ortega-Alonso A.
        Exercise in waist-high warm water decreases pain and improves health-related quality of life and strength in the lower extremities in women with fibromyalgia.
        Arthritis Rheum. 2006; 55: 66-73
        • Tomas-Carus P.
        • Gusi N.
        • Hakkinen A.
        • Hakkinen K.
        • Raimundo A.
        • Ortega-Alonso A.
        Improvements of muscle strength predicted benefits in HRQOL and postural balance in women with fibromyalgia: an 8-month randomized controlled trial.
        Rheumatology (Oxford). 2009; 48: 1147-1151
        • Prasartwuth O.
        • Taylor J.L.
        • Gandevia S.C.
        Maximal force, voluntary activation and muscle soreness after eccentric damage to human elbow flexor muscles.
        J Physiol. 2005; 567: 337-348
        • Marshall P.W.
        • Mannion J.
        • Murphy B.A.
        The eccentric, concentric strength relationship of the hamstring muscles in chronic low back pain.
        J Electromyogr Kinesiol. 2010; 20: 39-45
        • Dvir Z.
        Isokinetics: muscle testing, interpretation and clinical application.
        2nd ed. Churchill Livingstone, London2003
        • Frontera W.R.
        • Hughes V.A.
        • Dallal G.E.
        • Evans W.J.
        Reliability of isokinetic muscle strength testing in 45- to 78-year-old men and women.
        Arch Phys Med Rehabil. 1993; 74: 1181-1185
        • Sole G.
        • Hamren J.
        • Milosavljevic S.
        • Nicholson H.
        • Sullivan S.J.
        Test-retest reliability of isokinetic knee extension and flexion.
        Arch Phys Med Rehabil. 2007; 88: 626-631
        • Panton L.B.
        • Kingsley J.D.
        • Toole T.
        • et al.
        A comparison of physical functional performance and strength in women with fibromyalgia, age- and weight-matched controls, and older women who are healthy.
        Phys Ther. 2006; 86: 1479-1488
        • Henriksen M.
        • Lund H.
        • Christensen R.
        • et al.
        Relationships between the fibromyalgia impact questionnaire, tender point count, and muscle strength in female patients with fibromyalgia: a cohort study.
        Arthritis Rheum. 2009; 61: 732-739
        • Martin L.
        • Nutting A.
        • MacIntosh B.R.
        • Edworthy S.M.
        • Butterwick D.
        • Cook J.
        An exercise program in the treatment of fibromyalgia.
        J Rheumatol. 1996; 23: 1050-1053
        • Adsuar J.C.
        • Olivares P.R.
        • del Pozo-Cruz B.
        • Parraca J.A.
        • Gusi N.
        Test-retest reliability of isometric and isokinetic knee extension and flexion in patients with fibromyalgia: evaluation of the smallest real difference.
        Arch Phys Med Rehabil. 2011; 92: 1646-1651
        • Meeteren J.
        • Roebroeck M.E.
        • Stam H.J.
        Test-retest reliability in isokinetic muscle strength measurements of the shoulder.
        J Rehabil Med. 2002; 34: 91-95
        • Mannerkorpi K.
        • Svantesson U.
        • Carlsson J.
        • Ekdahl C.
        Tests of functional limitations in fibromyalgia syndrome: a reliability study.
        Arthritis Care Res. 1999; 12: 193-199
        • Munro B.H.
        • Visintainer M.A.
        • Page E.B.
        Statistical methods for health care research.
        JB Lippincott, Philadelphia1986
        • Leggin B.G.
        • Neuman R.M.
        • Iannotti J.P.
        • Williams G.R.
        • Thompson E.C.
        Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength.
        J Shoulder Elbow Surg. 1996; 5: 18-24
        • Wolfe F.
        • Smythe H.A.
        • Yunus M.B.
        • et al.
        The American College of Rheumatology 1990 Criteria for the Classification of Fibromyalgia. Report of the Multicenter Criteria Committee.
        Arthritis Rheum. 1990; 33: 160-172
        • Burckhardt C.S.
        • Clark S.R.
        • Bennett R.M.
        The fibromyalgia impact questionnaire: development and validation.
        J Rheumatol. 1991; 18: 728-733
        • Esteve-Vives J.
        • Rivera J.
        • Salvat M.I.
        • De Gracia M.
        • Alegre C.
        [Proposal for a consensus version of the Fibromyalgia Impact Questionnaire (FIQ) for the Spanish population] [Spanish].
        Reumatol Clin. 2007; 3: 21-24
        • Larsson B.
        • Karlsson S.
        • Eriksson M.
        • Gerdle B.
        Test-retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions.
        J Electromyogr Kinesiol. 2003; 13: 281-287
        • Shklar A.
        • Dvir Z.
        Isokinetic strength relationships in shoulder muscles.
        Clin Biomech (Bristol, Avon). 1995; 10: 369-373
        • Kannus P.
        • Beynnon B.
        Peak torque occurrence in the range of motion during isokinetic extension and flexion of the knee.
        Int J Sports Med. 1993; 14: 422-426
        • Shrout P.E.
        • Fleiss J.L.
        Intraclass correlations: uses in assessing rater reliability.
        Psychol Bull. 1979; 86: 420-428
        • Weir J.P.
        Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM.
        J Strength Cond Res. 2005; 19: 231-240
        • Atkinson G.
        • Nevill A.M.
        Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.
        Sports Med. 1998; 26: 217-238
        • Holmback A.M.
        • Porter M.M.
        • Downham D.
        • Lexell J.
        Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women.
        Scand J Rehabil Med. 1999; 31: 229-239
        • Bland J.M.
        • Altman D.G.
        Statistical methods for assessing agreement between two methods of clinical measurement.
        Lancet. 1986; 1: 307-310
        • Bassey E.J.
        • Ebrahim S.B.
        • Dallosso H.M.
        • Morgan K.
        Normal values for range of shoulder abduction in men and women aged over 65 years.
        Ann Hum Biol. 1989; 16: 249-257
        • Codine P.
        • Bernard P.L.
        • Pocholle M.
        • Herisson C.
        [Isokinetic strength measurement and training of the shoulder: methodology and results] [French].
        Ann Readapt Med Phys. 2005; 48: 80-92