Advertisement

Predicting Exercise Capacity Through Submaximal Fitness Tests in Persons With Multiple Sclerosis

      Abstract

      Kuspinar A, Andersen RE, Teng SY, Asano M, Mayo NE. Predicting exercise capacity through submaximal fitness tests in persons with multiple sclerosis.

      Objective

      To estimate, for persons with multiple sclerosis (MS), the extent to which peak oxygen consumption (Vo2peak) can be predicted by the results on submaximal tests.

      Design

      Cross-sectional study.

      Setting

      Three MS clinics in the Greater Montreal region, Canada.

      Participants

      A center-stratified random sample of 135 women and 48 men was drawn (N=183). A subgroup of 59 subjects with MS, who were able to perform the step test, was selected from this sample to complete the maximal exercise test.

      Interventions

      Not applicable.

      Main Outcome Measure

      Vo2peak.

      Results

      In this sample (mean age ± SD, 39 ± 9y; median Expanded Disability Status Scale=1.5), the mean Vo2peak ± SD was 27.6 ± 7.3mL·kg−1·min−1. This value is considerably low when compared with healthy persons, ranking below the 25th percentile for both men and women. In a multivariate regression analysis, the step test and grip strength were identified as the only significant predictors of Vo2peak. When combined with body weight, grip strength and the step test explained 74% of the variance in Vo2peak.

      Conclusions

      Patients with MS with a mild degree of disability exhibit marked reductions in exercise capacity. Also, in persons with MS, submaximal tests are good predictors of exercise capacity. These measures may be used in clinical settings to help assess and monitor maximum oxygen consumption and in research to evaluate the effect of exercise-related interventions. Furthermore, they will allow people with MS to self-monitor their exercise capacity and be more actively engaged in taking charge of their fitness level.

      Key Words

      List of Abbreviations:

      CHAMPS (Community Healthy Activities Model Program for Seniors), CNS (central nervous system), CPAFLA (Canadian Physical Activity Fitness and Lifestyle Appraisal), EDSS (Expanded Disability Status Scale), EQ-5D (EuroQol-5D), MAS (Modified Ashworth Scale), mCAFT (Modified Canadian Aerobic Fitness Test), MS (multiple sclerosis), 6MWT (six-minute walk test), RER (respiratory exchange ratio), RPE (rate of perceived exertion), VAS (visual analog scale), Vo2peak (peak oxygen consumption)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Archives of Physical Medicine and Rehabilitation
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Noseworthy J.H.
        • Lucchinetti C.
        • Rodriguez M.
        • Weinshenker B.G.
        Multiple sclerosis.
        N Engl J Med. 2000; 343: 938-952
        • O'Connor P.
        Key issues in the diagnosis and treatment of multiple sclerosis: an overview.
        Neurology. 2009; 59: S1-S33
        • Orton S.M.
        • Herrera B.M.
        • Yee I.M.
        • Valdar W.
        • Ramagopalan S.V.
        • Sadovnick A.D.
        • Ebers G.C.
        Sex ratio of multiple sclerosis in Canada: a longitudinal study.
        Lancet Neurol. 2006; 5: 932-936
        • White L.J.
        • Dressendorfer R.H.
        Exercise and multiple sclerosis.
        Sports Med. 2004; 34: 1077-1100
        • Motl R.W.
        • McAuley E.
        • Snook E.M.
        Physical activity and multiple sclerosis: a meta-analysis.
        Mult Scler. 2005; 11: 459-463
        • Noonan V.
        • Dean E.
        Submaximal exercise testing: clinical application and interpretation.
        Phys Ther. 2000; 80: 782-807
        • Niemen D.C.
        Exercise testing and prescription: a health-related approach.
        6th ed. McGraw-Hill Higher Education, New York2007
        • McGavin C.R.
        • Gupta S.P.
        • McHardy G.J.
        Twelve-minute walking test for assessing disability in chronic bronchitis.
        BMJ. 1976; 1: 822-823
        • Butland R.J.
        • Pang J.
        • Gross E.R.
        • Woodcock A.A.
        • Geddes D.M.
        Two-, six-, and 12-minute walking tests in respiratory disease.
        Br Med J (Clin Res Ed). 1982; 284: 1607-1608
        • Savci S.
        • Inal-Ince D.
        • Arikan H.
        • et al.
        Six-minute walk distance as a measure of functional exercise capacity in multiple sclerosis.
        Disabil Rehabil. 2005; 27: 1365-1371
        • Chetta A.
        • Rampello A.
        • Marangio E.
        • et al.
        Cardiorespiratory response to walk in multiple sclerosis patients.
        Respir Med. 2004; 98: 522-529
        • Goldman M.D.
        • Marrie R.A.
        • Cohen J.A.
        Evaluation of the six-minute walk in multiple sclerosis subjects and healthy controls.
        Mult Scler. 2008; 14: 383-390
        • Rejeski W.J.
        • Foley K.O.
        • Woodard C.M.
        • Zaccaro D.J.
        • Berry M.J.
        Evaluating and understanding performance testing in COPD patients.
        J Cardiopulm Rehabil. 2000; 20: 79-88
        • Riley M.
        • McParland J.
        • Stanford C.F.
        • Nicholls D.P.
        Oxygen consumption during corridor walk testing in chronic cardiac failure.
        Eur Heart J. 1992; 13: 789-793
        • Tesio L.
        • Perucca L.
        • Franchignoni F.P.
        • Battaglia M.A.
        A short measure of balance in multiple sclerosis: validation through Rasch analysis.
        Funct Neurol. 1997; 12: 255-265
        • Weller I.M.
        • Thomas S.G.
        • Gledhill N.
        • Paterson D.
        • Quinney A.
        A study to validate the modified Canadian Aerobic Fitness Test.
        Can J Appl Physiol. 1994; 20: 211-221
        • Weller I.M.
        • Thomas S.G.
        • Corey P.N.
        • Cox M.H.
        Prediction of maximal oxygen uptake from a modified Canadian Aerobic Fitness Test.
        Can J Appl Physiol. 1993; 18: 175-188
        • Jette M.
        • Campbell J.
        • Mongeon J.
        • Routhier R.
        The Canadian Home Fitness Test as a predictor for aerobic capacity.
        Can Med Assoc J. 1976; 114: 680-682
      1. CSEP Health & Fitness Program's Health-Related Appraisal & Counselling Strategy.
        in: The Canadian Physical Activity, Fitness and Lifestyle Approach. 3rd ed. Canadian Society for Exercise Physiology, Ontario2004
      2. Canadian Standardized Test of Fitness operations manual.
        3rd ed. Fitness Canada, Ottawa1986
        • Weller I.M.
        • Corey P.N.
        A study of the reliability of the Canada Fitness Survey questionnaire.
        Med Sci Sports Exerc. 1998; 30: 1530-1536
      3. ATS statement: guidelines for the six-minute walk test.
        Am J Respir Crit Care Med. 2002; 166: 111-117
        • Finch E.
        • Brooks D.
        • Stratford P.W.
        • Mayo N.E.
        Physical rehabilitation outcome measures: a guide to enhanced clinical decision making.
        Lippincott Williams & Wilkins, Ontario2002
        • Sayers S.P.
        • Harackiewicz D.V.
        • Harman E.A.
        • Frykman P.N.
        • Rosenstein M.T.
        Cross-validation of three jump power equations.
        Med Sci Sports Exerc. 1999; 31: 572-577
        • Payne N.
        • Gledhill N.
        • Katzmarzyk P.T.
        • Jamnik V.K.
        • Keir P.J.
        Canadian musculoskeletal fitness norms.
        Can J Appl Physiol. 2000; 25: 430-442
        • Mathiowetz V.
        • Weber K.
        • Volland G.
        • Kashman N.
        Reliability and validity of grip and pinch strength evaluations.
        J Hand Surg [Am]. 1984; 9: 222-226
        • Desrosiers J.
        • Hebert R.
        • Bravo G.
        • Dutil E.
        Comparison of the Jamar dynamometer and the Martin vigorimeter for grip strength measurements in a healthy elderly population.
        Scand J Rehabil Med. 1995; 27: 137-143
        • Paltamaa J.
        • West H.
        • Sarasoja T.
        • Wikstrom J.
        • Malkia E.
        Reliability of physical functioning measures in ambulatory subjects with MS.
        Physiother Res Int. 2005; 10: 93-109
        • Peolsson A.
        • Hedlund R.
        • Oberg B.
        Intra- and inter-tester reliability and reference values for hand strength.
        J Rehabil Med. 2001; 33: 36-41
        • Bohannon R.W.
        • Schaubert K.L.
        Test-retest reliability of grip-strength measures obtained over a 12-week interval from community-dwelling elders.
        J Hand Ther. 2005; 18 (quiz): 426-427
        • Schreuders T.A.
        • Roebroeck M.E.
        • Goumans J.
        • van Nieuwenhuijzen J.F.
        • Stijnen T.H.
        • Stam H.J.
        Measurement error in grip and pinch force measurements in patients with hand injuries.
        Phys Ther. 2003; 83: 806-815
        • Cox M.H.
        • Thomas S.G.
        • Weller I.M.
        • Corey P.
        Reliability and validity of a fitness assessment for epidemiological studies.
        Can J Sport Sci. 1992; 17: 49-55
        • Gibbons W.J.
        • Fruchter N.
        • Sloan S.
        • Levy R.D.
        Reference values for a multiple repetition 6-minute walk test in healthy adults older than 20 years.
        J Cardiopulm Rehabil. 2001; 21: 87-93
        • Kleinbaum D.G.
        • Kupper L.L.
        • Miller K.E.
        • Nizam A.
        Applied regression analysis and other multivariable methods.
        3rd ed. Brooks/Cole Publishing Co, Pacific Grove1998
        • Bjarnadottir O.H.
        • Konradsdottir A.D.
        • Reynisdottir K.
        • Olafsson E.
        Multiple sclerosis and brief moderate exercise: a randomised study.
        Mult Scler. 2007; 13: 776-782
        • Romberg A.
        • Virtanen A.
        • Aunola S.
        • Karppi S.L.
        • Karanko H.
        • Ruutiainen J.
        Exercise capacity, disability and leisure physical activity of subjects with multiple sclerosis.
        Mult Scler. 2004; 10: 212-218
        • Morrison E.H.
        • Cooper D.M.
        • White L.J.
        • et al.
        Ratings of perceived exertion during aerobic exercise in multiple sclerosis.
        Arch Phys Med Rehabil. 2008; 89: 1570-1574
        • Dalgas U.
        • Stenager E.
        • Ingemann-Hansen T.
        Multiple sclerosis and physical exercise: recommendations for the application of resistance-, endurance- and combined training.
        Mult Scler. 2008; 14: 35-53
        • Cahalin L.
        • Pappagianopoulos P.
        • Prevost S.
        • Wain J.
        • Ginns L.
        The relationship of the 6-min walk test to maximal oxygen consumption in transplant candidates with end-stage lung disease.
        Chest. 1995; 108: 452-459
        • Miyamoto S.
        • Nagaya N.
        • Satoh T.
        • et al.
        Clinical correlates and prognostic significance of six-minute walk test in patients with primary pulmonary hypertension: comparison with cardiopulmonary exercise testing.
        Am J Respir Crit Care Med. 2000; 161: 487-492
        • Montgomery P.S.
        • Gardner A.W.
        The clinical utility of a six-minute walk test in peripheral arterial occlusive disease patients.
        J Am Geriatr Soc. 1998; 46: 706-711
        • Hendrican M.C.
        • McKelvie R.S.
        • Smith T.
        • et al.
        Functional capacity in patients with congestive heart failure.
        J Card Fail. 2000; 6: 214-219
        • Eng J.J.
        • Chu K.S.
        • Dawson A.S.
        • Kim C.M.
        • Hepburn K.E.
        Functional walk tests in individuals with stroke: relation to perceived exertion and myocardial exertion.
        Stroke. 2002; 33: 756-761
        • Rantanen T.
        • Masaki K.
        • Foley D.
        • Izmirlian G.
        • White L.
        • Guralnik J.M.
        Grip strength changes over 27 yr in Japanese-American men.
        J Appl Physiol. 1998; 85: 2047-2053
        • Rantanen T.
        • Guralnik J.M.
        • Foley D.
        • et al.
        Midlife hand grip strength as a predictor of old age disability.
        JAMA. 1999; 281: 558-560
        • Sasaki H.
        • Kasagi F.
        • Yamada M.
        • Fujita S.
        Grip strength predicts cause-specific mortality in middle-aged and elderly persons.
        Am J Med. 2007; 120: 337-342
        • Gale C.R.
        • Martyn C.N.
        • Cooper C.
        • Sayer A.A.
        Grip strength, body composition, and mortality.
        Int J Epidemiol. 2007; 36: 228-235
        • Ali N.A.
        • O'Brien Jr, J.M.
        • Hoffmann S.P.
        • et al.
        Acquired weakness, handgrip strength, and mortality in critically ill patients.
        Am J Respir Crit Care Med. 2008; 178: 261-268