« Previous
Next »
Archives of Physical Medicine and Rehabilitation
Volume 90, Issue 6
, Pages
1048-1054
, June 2009
Assessment of Gluteus Maximus Muscle Area With Different Image Analysis Programs
-
CT scan image locations used for assessments. (A), C1: between the second and third sacral notch; (B), C2: caudal head of the femur appears; (C), C3: greater trochanter is most prominent. NOTE. outlin
CT scan image locations used for assessments. (A), C1: between the second and third sacral notch; (B), C2: caudal head of the femur appears; (C), C3: greater trochanter is most prominent. NOTE. outlined dotted area is the gluteus maximus. Inset square 6 × 6cm2 on top left used as reference for VeVMD measurements.
-
Histograms showing differences in repeated measurements to the mean measurement for each muscle using (A) ImageJ and (B) VeVMD. — — — R1, – – – – R2, ------ R3, —·—· R4.Histograms showing differences in repeated measurements to the mean measurement for each muscle using (A) ImageJ and (B) VeVMD. — — — R1, – – – – R2, ------ R3, —·—· R4.
-
Bland-Altman analysis for each rater between image analysis programs. The analysis compares the difference in measurement to the mean measurement. Y describes the trendline for each rater. Dotted lineBland-Altman analysis for each rater between image analysis programs. The analysis compares the difference in measurement to the mean measurement. Y describes the trendline for each rater. Dotted lines signify 2 SDs 2*SD=6.51, 7.42, 5.73, 4.21, respectively. (A) •R1 (circle), (B) ■R2 (square), (C) ♦R3 (diamond), (D) ▲R4 (triangle).
-
Longitudinal study for 1 patient. (A) Main effects and (B) interaction plot for 4 raters and 2 different programs over a period of 24 months. •R1 (circle), ■R2 (square), ♦R3 (diamond), ▲R4 (triangle),Longitudinal study for 1 patient. (A) Main effects and (B) interaction plot for 4 raters and 2 different programs over a period of 24 months. •R1 (circle), ■R2 (square), ♦R3 (diamond), ▲R4 (triangle), ○Image J (empty circle), ☐VeVMD (empty square).
-
Interval plot of measurements using (A) ImageJ and (B) VeVMD. Interval bars represent 95% confidence interval for the mean. Measurements of gluteus maximus muscle at the slice where the caudal head ofInterval plot of measurements using (A) ImageJ and (B) VeVMD. Interval bars represent 95% confidence interval for the mean. Measurements of gluteus maximus muscle at the slice where the caudal head of femur appears (C2) on the right side. Tables show significance of measurement differences between time points. Abbreviation: NS, not significant. *P<.05; **P<.01. •R1 (circle), ■R2 (square), ♦R3 (diamond), ▲R4 (triangle).
Supported by the Veterans Administration Rehabilitation Research and Development Service (grant no. B4664).
No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit on the authors or on any organization with which the authors are associated.
PII: S0003-9993(09)00141-5
doi: 10.1016/j.apmr.2008.12.009
« Previous
Next »
Archives of Physical Medicine and Rehabilitation
Volume 90, Issue 6
, Pages
1048-1054
, June 2009