« Previous
Next »
Archives of Physical Medicine and Rehabilitation
Volume 89, Issue 3
, Pages
399-403
, March 2008
Whole Body Vibration Versus Conventional Physiotherapy to Improve Balance and Gait in Parkinson’s Disease
-
Galileo device for WBV. During WBV the right and left leg are thrust upward with a frequency of 25Hz and an amplitude of 7 to 14mm. Reprinted by permission of Novotec Medical Systems, Pforzheim, Germa
Galileo device for WBV. During WBV the right and left leg are thrust upward with a frequency of 25Hz and an amplitude of 7 to 14mm. Reprinted by permission of Novotec Medical Systems, Pforzheim, Germany.
-
Tilt board used for dynamic posturography. The tilt board consists of a platform with a cylindrical curved base. The virtual axis of the tilt board is located outside the support surface and changes wTilt board used for dynamic posturography. The tilt board consists of a platform with a cylindrical curved base. The virtual axis of the tilt board is located outside the support surface and changes with every platform movement. The design of the tilt board makes the subject unable to stand still because there is continuous need for compensatory shifts of posture to keep balance. While the subject is standing on the tilt board, displacements of the base are registered as a measure of performance.
No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the authors or upon any organization with which the authors are associated.
PII: S0003-9993(07)01812-6
doi: 10.1016/j.apmr.2007.09.031
© 2008 American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
« Previous