Archives of Physical Medicine and Rehabilitation
Volume 88, Issue 7 , Pages 907-915 , July 2007

Reproducibility of Loading Measurements With Skin-Mounted Accelerometers During Walking

  • Tuomas Liikavainio, MD, MSc

      Affiliations

    • Department of Physical and Rehabilitation Medicine, Kuopio University Hospital, Kuopio, Finland
    • Corresponding Author InformationReprint requests to Tuomas Liikavainio, MD, MSc, Dept of Physical and Rehabilitation Medicine, Kuopio University Hospital, PO Box 1777, FIN-70211 Kuopio, Finland
  • ,
  • Timo Bragge

      Affiliations

    • Department of Physics, University of Kuopio, Kuopio, Finland
  • ,
  • Marko Hakkarainen, MSc

      Affiliations

    • Department of Physics, University of Kuopio, Kuopio, Finland
  • ,
  • Jukka S. Jurvelin, PhD

      Affiliations

    • Department of Physics, University of Kuopio, Kuopio, Finland
  • ,
  • Pasi A. Karjalainen, PhD

      Affiliations

    • Department of Physics, University of Kuopio, Kuopio, Finland
  • ,
  • Jari P. Arokoski, MD, DMSc

      Affiliations

    • Department of Physical and Rehabilitation Medicine, Kuopio University Hospital, Kuopio, Finland
    • Institute of Clinical Medicine, University of Kuopio, Kuopio, Finland.

References 

  1. Radin EL, Whittle MW, Yang KH, et al. The heelstrike transient, its relationship with the angular velocity of the shank, and the effect of quadriceps paralysis. In:  Lantz SH,  King AI editor. Advances in bioengineering. New York: American Society of Mechanical Engineers; 1986;p. 121–123
  2. Voloshin A, Wosk J. An in vivo study of low back pain and shock absorption in the human locomotor system. J Biomech. 1982;15:21–27
  3. Wosk J, Voloshin AS. Low back pain: conservative treatment with artificial shock absorbers. Arch Phys Med Rehabil. 1985;66:145–148
  4. Light LH, McLellan GE, Klenerman L. Skeletal transients on heel strike in normal walking with different footwear. J Biomech. 1980;13:477–480
  5. Auvinet B, Berrut G, Touzard C, et al. Reference data for normal subjects obtained with an accelerometric device. Gait Posture. 2002;16:124–134
  6. Currie G, Rafferty D, Duncan G, Bell F, Evans AL. Measurement of gait by accelerometer and walkway: a comparison study. Med Biol Eng Comput. 1992;30:669–670
  7. Mayagoitia RE, Nene AV, Veltink PH. Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. J Biomech. 2002;35:537–542
  8. Moe-Nilssen R, Helbostad JL. Estimation of gait cycle characteristics by trunk accelerometry. J Biomech. 2004;37:121–126
  9. Folman Y, Wosk J, Voloshin A, Liberty S. Cyclic impacts on heel strike: a possible biomechanical factor in etiology of degenerative disease of the human locomotor system. Arch Orthop Trauma Surg. 1986;104:363–365
  10. Gill HS, O’Connor JJ. Heelstrike and the pathomechanics of osteoarthrosis: a pilot gait study. J Biomech. 2003;36:1625–1631
  11. Lafortune MA, Henning E, Valiant GA. Tibial shock measured with bone and skin mounted transducers. J Biomech. 1995;28:989–993
  12. Loy DJ, Voloshin AS. Biomechanics of stair walking and jumping. J Sports Sci. 1991;9:137–149
  13. Wosk J, Voloshin A. Wave attenuation in skeletons of young healthy persons. J Biomech. 1981;14:261–267
  14. Kinoshita H, Ogawa T, Kuzuhara K, Ikuta K. In vivo examination of the dynamic properties of the human heel pad. Int J Sports Med. 1993;14:312–319
  15. Kinoshita H, Francis PR, Murase T, Kawai S, Ogawa T. The mechanical properties of the heel pad in elderly adults. Eur J Appl Physiol Occup Physiol. 1996;73:404–409
  16. Lafortune MA, Hennig EM. Cushioning properties of footwear during walking: accelerometer and force platform measurement. Clin Biomech. 1992;7:181–184
  17. Boyer KA, Nigg BM. Muscle activity in the leg is tuned in response to impact force characteristics. J Biomech. 2004;37:1583–1588
  18. Wakeling JM, Liphardt AM, Nigg BM. Muscle activity reduces soft-tissue resonance at heel-strike during walking. J Biomech. 2003;36:1761–1769
  19. Nokes L, Fairclough JA, Mintowt-Czyz WJ, Mackie I, Williams J. Vibration analysis of human tibia: the effect of soft tissue on the output from skin-mounted accelerometers. J Biomed Eng. 1984;6:223–226
  20. Saha S, Lakes RS. The effect of soft tissue on wave-propagation and vibration tests for determining the in vivo properties of bone. J Biomech. 1977;10:393–401
  21. Ziegert JC, Lewis JL. The effect of soft tissue on measurements of vibrational bone motion by skin-mounted accelerometers. J Biomech Eng. 1979;101:218–220
  22. Moe-Nilssen R. Test-retest reliability of trunk accelerometry during standing and walking. Arch Phys Med Rehabil. 1998;79:1377–1385
  23. Henriksen M, Lund H, Moe-Nilssen R, Bliddal H, Danneskiod-Samsoe B. Test-retest reliability of trunk accelerometric gait analysis. Gait Posture. 2004;19:288–297
  24. Gillespie KA, Dickey JP. Determination of the effectiveness of materials in attenuating high frequency shock during gait using filterbank analysis. Clin Biomech (Bristol, Avon). 2003;18:50–59
  25. Chen WL, O’Connor JJ, Radin EL. A comparison of the gaits of Chinese and Caucasian women with particular reference to their heelstrike transients. Clin Biomech (Bristol, Avon). 2003;18:207–213
  26. McCrory JL, White SC, Lifeso RM. Vertical ground reaction forces: objective measures of gait following hip arthroplasty. Gait Posture. 2001;14:104–109
  27. Stacoff A, Diezi C, Luder G, Stussi E, Kramers-de Quervain IA. Ground reaction forces on stairs: effects of stair inclination and age. Gait Posture. 2005;21:24–38
  28. Giakas G, Baltzopoulos V. Time and frequency domain analysis of ground reaction forces during walking: an investigation of symmetry and variability. Gait Posture. 1997;5:189–197
  29. White R, Agouris I, Selbie RD, Kirkpatrick M. The variability of force platform data in normal and cerebral palsy gait. Clin Biomech (Bristol, Avon). 1999;14:185–192
  30. Herzog W, Nigg BM, Read LJ, Olsson E. Asymmetries in ground reaction force patterns in normal human gait. Med Sci Sports Exerc. 1989;21:110–114
  31. Kavanagh JJ, Morrison S, James DA, Barrett R. Reliability of segmental accelerations measured using a new wireless gait analysis system. J Biomech. 2006;39:2863–2872
  32. Kadaba MP, Ramakrishnan HK, Wootten ME, Gainey J, Gorton G, Cochran GV. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. J Orthop Res. 1989;7:849–860
  33. Winter DA. Kinematic and patterns in human gait: variability and compensating effects. Hum Mov Sci. 1984;3:51–56
  34. O’Connor JJ, Johnston I. Transmission of rapidly applied load through articular cartilage: the mechanics of osteoarthrosis. In:  Turner-Smith AR editors. Micromovement in orthopaedics. Oxford: Clarendon Pr; 1993;p. 244–268
  35. Greig C, Butler F, Skelton D, Mahmud S, Young A. Treadmill walking in old age may not reproduce the real life situation. J Am Geriatr Soc. 1993;41:15–18
  36. Schmidt RA. Motor control and learning: a behavioral emphasis. 2nd ed. Champaign: Human Kinetics; 1997;

 Supported by the Finnish Cultural Foundation and EVO (grant no. 5960416) from Kuopio University Hospital.No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the author(s) or upon any organization with which the author(s) is/are associated.

PII: S0003-9993(07)00260-2

doi: 10.1016/j.apmr.2007.03.031

Archives of Physical Medicine and Rehabilitation
Volume 88, Issue 7 , Pages 907-915 , July 2007